Coin Purses
3 Phase Electric Panel Meter
2023-12-12 06:04  Visit:135
Price:Unfilled
Send inquiry
Overview

The PC200S electric panel meters are compact panel-mounted power measurement and control instruments. They are equipped with integrated data acquisition and control features. With DI/DO, AI/AO modules, different components, such as instruments, relays, transformers, etc., can be replaced to meet the needs of various applications.

 

Products Description

As a board mounted instrument, PMC200S accomplishes precise estimation of exceptionally nonlinear burdens in view of the estimation of rms. High level matrix recurrence synchronous testing innovation empowers it to precisely gauge an extensive variety of force boundaries, including voltage/current, recurrence, power, power element, energy and current/voltage sounds.

Contrasted and customary energy meters, PMC200S has the two information obtaining and control capabilities, minimized size, simple to send and cost saving elements, and can be broadly utilized in energy the board frameworks, substation mechanization, appropriation network computerization, local area power circulation, modern robotization, power plant power frameworks, clever structures, smart conveyance boards, high and low voltage switchgear and different situations.

By utilizing the PMC200S, you can acquire bits of knowledge into power load conditions, distinguish top energy utilization periods, and go to designated energy-saving lengths. Our item offers a 485 correspondence interface, permitting you to collaborate with different gadgets and shrewd frameworks, empowering more clever energy the board.

We are focused on furnishing you with far reaching and dependable energy checking and the board arrangements, assisting you with accomplishing energy-saving and outflow decrease objectives while working on cost-viability. Pick our multifunctional meter, and you will appreciate cutting edge innovation, helpful activity, and a strong quality assurance.

 

Features

 

Main features

Instantaneous true RMS value

Current

each single phase and conjunction, average

ULN/ULL

each single phase and conjunction, average

Active, reactive, apparent power

each phase and the sum of three phases

PF

each phase and the sum of three phases

Frequency

45~65Hz

Maximum/minimum value

Max/min rms current

Max/min rms phase voltage

Max/min total active, reactive, apparent power

Max/min total PF

Max/min frequency

Max/min THD I and THD U

Demand and peak demand value

Current per phase

current value/peak/month end peak

Total kWh, kvarh, kVAh

current value/peak/month end peak

Energy

Input/output/total kWh

1 pulse output

Input/output/total kvarh

1 pulse output

kVAh

Compound rate of electrical energy

8 recharge periods, 4 rates can be set

Power quality

Total Harmonic Distortion Rate (THD)

current and voltage

1st-31st harmonic analysis

current and voltage

Voltage peak coefficient CF and current K coefficient

Event logging

100 SOE event records

Alarm system

8 configurable limit alarm channels

4 configurable logical alarm channels

Communication

RS-485 /MODBUS-RTU protocol

Display

STN LCD display

Real-time clock

Year, month, day, minute, second

Other

Program online upgrade supported

 

Optional features

Digital Input (DI) module (optional)

4 switching inputs

Digital Output (DO) module (optional)

2 relay outputs, which can be set by local overrun alarm or controlled remotely

Analog Input (AI)/Output (AO) module (optional)

A total of 2 channels. Optional 4-20mA DC analog input, 0-5V DC analog input, 4-20mA DC analog output

 

Specifications

 

Electrical characteristics

System

Three-phase three-wire AC system, three-phase four-wire AC system;

Sample rate

128 samples per cycle

Data refresh rate

1s

Measurement accuracy

Current

±0.2%FS

Voltage

±0.2%FS

Power

0.5S

Frequency

±0.001Hz

Active energy

0.5S

Reactive energy

1.0S

DC input (AI)

0.5% FS

DC output (AO)

0.5% FS

Voltage input

Measure voltage

3*220/380V(Direct input)

3*57.7/100V (PT secondary)

Overload

1.2x/continuous

Input impedance

300KΩ

Current input

Measure current

5A (CT secondary) or 1A (CT secondary)

Overload

1.2x/continuous

Input impedance

<0.1Ω

Digital input

Operating voltage

12~24VDC

Input impedance

12KΩ

Isolation voltage

2KV

Digital output

Node type

Mechanical contacts

Node capacity

220 VAC/5A、30 VDC/5A

4-20mA DC input measurement

Measure current

4~20mA

Allowed overload capacity

1.2x/continuous

Input impedance

10Ω

Isolation voltage

2KV

0-5V DC input measurement

Measure voltage

0~5V

Allowed overload capacity

1.2x/continuous

Input impedance

12.5KΩ

Isolation voltage

2KV

4-20mA DC output

Open-circuit voltage

15VDC

Load capacity

≤600Ω

Isolation voltage

2KV

Working power supply

AC

100~240VAC/45~65Hz

DC

100~375 VDC

power consumption

< 3W

Mechanical characteristic

Weight

0.5kg

IP protection rating

Instrument panel IP52, instrument body IP30

Size

host

96 *96 * 72 mm

Host + module

96 * 96 * 120 mm

Operating temperature

display

-20~70°C

Instrument

-25~70°C

Storage temperature

instrument + display

-40~85°C

Humidity

5% ~ 90%RH, non-condensing

Electromagnetic compatibility

Electrostatic discharge

IEC 61000-4-2,Level 4

Fast transient

IEC 61000-4-4,Level 4

Surges

IEC 61000-4-5,Level 3

Magnetic fields

IEC 61000-4-8,Level 3

Electrical insulation

Insulation resistance

GB/T13729,>50MΩ

AC voltage

GB/T13729, AC 2KV 50Hz /1min

Impulse voltage

GB/T13729,5KV,1.2/50us

 

Dimensions

The instrument's dimensions are listed below.

 

Mounting

Insert the meter into the 90mm*90mm cutting slot and secure it with the buckle.

 

Application

As shown in the figure below, the instrument is in the collection layer and is responsible for the measurement and collection of power data for each loop. At the same time, the instrument equipped with DI/DO, AI/AO modules can realize switch status monitoring, relay output, DC voltage and current input monitoring, and transmitter, which can also be customized to your specifications.

Ordering guide

 

Model code: PMC200S-(1)-(2)-(3)-(4)-(5).

(1)Input voltage and current:

1

57.7/100V rated measurement voltage, 5A rated measurement current.

2

57.7/100V rated measurement voltage, 1A rated measurement current.

3

220/380V rated measurement voltage, 5A rated measurement current.

4

220/380V rated measurement voltage, 1A rated measurement current.

(2)Power supply:

1

Power supply: 85~264 VAC/45~65Hz, 100~300 VDC.

(3)DI:

0

No DI

4

4-way DI

(4)Optional:

0

No optional

1

Optional 1 relay output (RL1+, RL1-port).

2

Optional 2 relay outputs

(5)AI&AO:

ab

"a" is for selecting the AI/AO module for AIO1 port, and "b" is for selecting the AI/AO module for AIO2 port. The optional modules are:

0 - None

1 - 5V DC analog input measurement (AI)

2 - 420mA DC analog input measurement (AI)

3 - 4~20mA DC analog output (AO)

For example, "ab = 00" means the AI/AO module is not selected for AIO1 port, and the AI/AO module is not selected for AIO2 port. "ab = 12" means the AIO1 port is equipped with the 5V DC analog input measurement module, and the AIO2 port is equipped with the 420mA DC analog input measurement module.

 

About Us

Founded in 2014, Kingnen Co., Ltd. is a professional manufacturer of power system debugging equipment and intelligent measurement and control instruments. We specialize in independent research and development, production, and sales. We are a national high-tech enterprise and have obtained the Shenzhen Double Soft Certification. Our company is located at Building CD, Block 4, Tian'an Digital City, Shenzhen, China, occupying 1,500 square meters of office space and a 3,000 square meter factory.

 

After-Sales Service

We promise to provide excellent product quality assurance and comprehensive after-sales service support as agreed, ensuring your satisfaction. We guarantee transparent warranty terms and will strictly fulfill our contractual obligations, allowing you to enjoy long-term warranty benefits. During the agreed after-sales service period, we provide free professional services to address all your concerns. Even after the service period, we will negotiate reasonable charges with you to ensure that you continue to receive high-quality service without additional burdens.

 

FAQ

1.Are expansion modules necessary?
Input/output expansion modules are not necessary, but they allow for features such as switch status monitoring, relay outputs, DC voltage and current input monitoring, and transmitters. We can also provide customization based on your specific requirements.

 

2.How many PMC200S can be configured under the same acquisition node?
Using a Category 5e shielded twisted pair cable, you can configure up to 32 devices under the same node. If there are no repeaters, the total bus length should not exceed 1200 meters.

 

http://www.kingnenmeter.com/

Message

TO: kaixianxinneng

E-mail:

Content:

Contact information
Company:KINGNEN Technology Co., Ltd.
Status:Offline Send a letter
Name:kaixianxinneng(Mr.)
Tel:+86-755-88353953
Phone:18038042351
Fax:+86-755-88352611
Area:Beijing
Address:6/F-3, Block 4-CD, TianAn Cyber Park, Shenzhen, China
Zip code:518048
Mail:info@kingnen.com
Homepage:http://www.kingnenmeter.com/
Linkurl:http://kaixianxinneng.cnjinshuwang.net/
Comment
0